Single fire hydrant valves are essential components of fire protection systems, providing a crucial connection point for firefighters to access water for extinguishing fires. These valves are typically located near buildings or other structures at risk of fire, ensuring that firefighters can quickly access a water source to control the fire effectively. This product plays a critical role in fire protection systems by providing a readily accessible water source for firefighters. They are essential for ensuring that firefighters can effectively act on the fires, protecting lives and property. Regular maintenance and inspection of these valves are crucial to ensure their proper functioning ,in case of an emergency. These valves consist of several key components that work together to regulate water flow and provide a safe and reliable connection for firefighters.
These components include:When firefighters arrive at the scene of a fire, they will locate the nearest fire hydrant and connect their hoses to the valve outlet. To open the valve, they will turn the valve operator counterclockwise until the water flow is established. They can then adjust the water flow by turning the valve operator further. Once the fire is extinguished, firefighters will close the valve by turning the valve operator clockwise until it stops. This will stop the flow of water and prevent any further water damage.
TYPE | SINGLE HEADED OBLIQUE TYPE |
INLET | "FLANGED -FLAT FACED (PCD: 160 mm, Holes: 4 no’s x 19mm Dia, flange: 200mm OD x 12 mm thk)" |
OUTLET | OUTLET OF 63 MM FEMALE INSTANTENEOUS COUPLING WITH LUGS |
DESIGN STD | IS:5290 - 1993 TYPE - A |
OPERATION | BY HAND WHEEL |
STEM | RISING |
HYDRAULIC TEST PRESSURE | 21 KGF/SQ.CM FOR 150 secs |
WATER TIGHTNESS | 14 KGF/SQ.CM FOR 150 secs |
FLOW TEST | 900 LPM AT 7 Kg/cm2 |
PAINTING | PO RED shade as per IS 538, of IS:5 |
MOC | AVAILABLE IN GM / SS / AL MOC |
APPROVAL | ISI MARKED |
At SPG Solutions, we stand as a prominent provider of superior fire extinguishing products and associated accessories. We are committed to deliver exceptional and distinctive products that align with the quality standards and comply with industry regulations. Timely fulfillment of all delivery orders is what we practice, ensuring utmost customer satisfaction. Our well earned reputation for quality in the industry is a testament to the dedication of our staff, consistently striving to complete customer orders ahead of the planned schedule.
Product introduction:A double hydrant fire extinguishing valve consists of a valve body which has the internal mechanism that controls water flow. Typically made up of cast iron to withstand high water pressure. This mechanism is protected by a valve bonnet which is bolted to the valve body. One of the important part of double hydrant system is a spindle that connects valve operator to the valve plug. The disc that regulates the flow of water throughout the valve is called as the valve plug. Further more, there are rubber made valve rings that seal against the valve plug when they are closed. There are outlet caps which have the responsibility of protecting the instrument from dirt and other unwanted particles.
The double hydrant fire valve functions in a typical manner. To open a double hydrant fire extinguishing valve, firefighters will connect their hoses to the valve outlets and turn the valve operator, typically a hand wheel, counterclockwise until the water flow is established. They can then adjust the water flow by turning the valve operator further. Once the fire is extinguished, firefighters will close the valve by turning the valve operator clockwise until it stops. This will stop the flow of water and prevent any further water damage.
Applications :TYPE | DOUBLE HEADED OBLIQUE TYPE |
INLET | "FLANGED -FLAT FACED (PCD: 180 mm, Holes: 8 no’s x 19mm Dia, flange: 220mm OD x 12 mm thk)" |
OUTLET | OUTLET OF 63 MM FEMALE INSTANTENEOUS COUPLING WITH LUGS |
DESIGN STD | IS:5290 - 1993 TYPE - B |
OPERATION | BY HAND WHEEL |
STEM | RISING |
HYDRAULIC TEST PRESSURE | 21 KGF/SQ.CM FOR 150 secs |
WATER TIGHTNESS | 14 KGF/SQ.CM FOR 150 secs |
FLOW TEST | 1800 LPM AT 7 Kg/cm2 |
PAINTING | PO RED shade as per IS 538, of IS:5 |
MOC | AVAILABLE IN GM / SS / AL MOC |
APPROVAL | ISI MARKED |